Punch biopsy needle 3 mm blade 7 mm

Punch biopsy needle 3 mm blade 7 mm

Non disponibile
€3.66
Tax included

3 mm punch biopsy needle 7 mm blade: 3 mm punch biopsy needle for skin sampling. Sharp circular blade in stainless steel, disposable, for veterinary dermatological diagnosis.

Description

3 mm punch biopsy needle with 7 mm blade is a surgical instrument designed for performing percutaneous biopsies and skin punches in a clinical and surgical environment. It is a device that combines the precision of a biopsy needle with the cutting surface provided by a 7 mm blade, designed to allow the healthcare professional to obtain representative tissue samples with a 3 mm diameter sampling hole. The product is described by the technical-functional name "3 mm punch biopsy needle, 7 mm blade" which identifies its main dimensional characteristics and intended use.

The "needle + punch" configuration allows a minimally invasive sampling procedure, aimed at reducing trauma to the surrounding tissues and facilitating post-operative management of the biopsy site. This instrument is intended for use by qualified healthcare professionals, in contexts where the collection of samples for histological, cytological or biomolecular examinations is required. The 3 mm punch biopsy needle with 7 mm blade is particularly suitable when you need a sample of small diameter but of adequate quality for differential diagnoses and detailed pathological analyses.

This descriptive sheet offers a complete overview of the indications, composition, contraindications, precautions for use, methods of use and practical recommendations relating to the 3 mm punch biopsy needle with 7 mm blade. All information is provided to support the correct clinical management of the instrument and to help healthcare personnel evaluate the risks and benefits of the biopsy procedure.

Therapeutic Indications

The 3 mm punch biopsy needle with 7 mm blade is indicated for the collection of superficial and subcutaneous tissue samples using the punch/biopsy technique in cases where it is necessary to obtain representative diagnostic material with minimal invasiveness. The indications include, by way of example and not exhaustively, the collection of skin tissue for histological examinations aimed at evaluating dermatological lesions, suspicions of skin neoplasia, checks for chronic inflammation, histopathological investigations for skin pathologies and targeted sampling for cytological or biomolecular studies. The 3 mm punch biopsy needle with 7 mm blade allows you to acquire a tissue cylinder with a technique that reduces damage to adjacent tissues compared to more invasive samples, at the same time facilitating execution in the clinic or operating room under local anesthesia when indicated.

This instrument can be used in diagnostic procedures where a small diameter sample is required but with clear margins and sufficient tissue integrity for microscopic analysis; the 7 mm blade facilitates clean cutting of the tissue while the 3 mm size of the punch ensures a controlled and standardized sampling hole. Use is reserved for operators trained in the biopsy technique: the choice to use the 3 mm punch biopsy needle with 7 mm blade must be made on the basis of the clinical evaluation of the patient, the site of the lesion, the dimensions and depth of the tissue to be taken, as well as in relation to the specific diagnostic objectives. Before use, it is advisable to plan the procedure considering the type of analysis required by the laboratory and the need to preserve certain portions of tissue for histological, immunohistochemical or molecular techniques.

The procedure with a 3 mm punch biopsy needle and a 7 mm blade is also indicated in contexts in which the minimization of bleeding and skin trauma is a priority, such as in patients with fragile skin or in anatomical areas with limited possibility of surgical closure. However, the clinical decision should always consider the risk-benefit relationship: for lesions that are very deep, extensive or require wider margins for diagnosis or treatment, alternative biopsy techniques may be preferred. The 3 mm punch biopsy needle with 7 mm blade therefore represents a specific diagnostic option for targeted and minimally invasive samples that require a sample of small dimensions but adequate for laboratory analysis.

Composition

The description "biopsy needle punch 3 mm blade 7 mm" mainly defines two dimensional and functional characteristics: the diameter of the punch (3 mm) and the size of the blade associated with the cutting movement (7 mm). The typical structural composition of an instrument with these characteristics includes design elements that guarantee rigidity, precision and biocompatibility of the surfaces in contact with the tissues. The main components include the needle-like tip for introduction and centering, the cylindrical section of the punch that delimits the 3 mm diameter sample and the cutting/blade portion that operates on the outer edge to detach the tissue cylinder with clean margins. These elements are designed to ensure controlled sampling, minimize the risk of crushing the sample and preserve the histological architecture necessary for the diagnostic examination.

The surfaces in contact with the tissue are treated and finished to reduce friction and improve sliding during the entry and rotation of the punch: the geometry of the 7 mm blade is calibrated to provide a uniform cutting edge that facilitates the detachment of the tissue cylinder from the desired depth. Even if the wording uses technical terms (needle, punch, blade), the actual composition and materials used must always meet the criteria of biological compatibility, corrosion resistance and ability to maintain the sharpness of the edge during use. In clinical protocols it is also essential that the instrument is supplied sterile and packaged in such a way as to preserve the integrity and asepsis of the blade and needle body until the moment of use.

For optimal diagnostic use of the 3 mm punch biopsy needle with 7 mm blade, it is important that the collected sample is not subjected to compression or mechanical injury that could alter the histological interpretation; the composition and geometry of the device are therefore designed to obtain a section that is as representative as possible, with clear margins and without excessive crushing. The attention to design also includes ergonomic aspects for the professional, with non-sterile parts possibly isolated by handles or safety systems that facilitate grip and control of the depth of penetration. Finally, for reasons of traceability and compliance with safety standards, the instrument packaging should specify the technical-functional name of the product, while this sheet provides the description based exclusively on the identification string "punch biopsy needle 3 mm blade 7 mm".

Contraindications

The use of the 3 mm punch biopsy needle with 7 mm blade may be contraindicated in the presence of clinical conditions that significantly increase the risk of bleeding, transmission of infection or compromise of local healing. The main contraindications include incorrect bleeding conditions or uncompensated coagulopathies, anticoagulant or antiaggregating therapies that have not been adequately evaluated and managed by the clinical team, and active local infections at the sampling site that may contaminate the sample or worsen the infectious situation. The use of the 3 mm punch biopsy needle with 7 mm blade should be avoided in situations in which the lesion is located close to anatomical structures where a percutaneous sampling could cause damage (for example intense superficial vascularization, superficial nervous structures that are not easily isolable or regions in which tissue loss could compromise function), unless it is not possible to adopt adequate protection and control measures.

Further contraindications include the impossibility of obtaining adequate informed consent from the patient or guardian, the absence of qualified personnel or tools and materials for the management of any immediate complications (such as acute bleeding), as well as serious unstabilized systemic conditions that make even a minimal surgical procedure risky. In patients with marked skin fragility or atrophic tissues, the risk of extensive skin damage or unwanted scarring may make an alternative sampling technique or referral to a center with specific expertise preferable.

Finally, the use of the 3 mm punch biopsy needle with 7 mm blade is not indicated in the absence of adequate sterility or when the instrument appears compromised, damaged or altered in the geometry of the blade; the use of devices that are not intact increases the risk of complications and non-diagnostic samples. It is therefore essential to carry out a check before use and not to use the instrument if the sterile packaging is open or compromised.

Safety of the drug for the species

The "Safety of the drug for the species" section, adapted to the context of the instrument described, concerns the safety of use of the 3 mm punch biopsy needle with 7 mm blade with respect to the patient and the species treated; in this context it must be underlined that it is a device and not a drug, therefore safety assessments focus on procedural risks, tissue compatibility and management of complications. Safety is guaranteed by the correct operating technique, the appropriateness of patient selection and the guarantee of sterility and integrity of the device: the adoption of good clinical practices reduces the probability of infection, bleeding and alteration of the diagnostic sample. The operator must preliminarily evaluate the patient's general condition, the presence of systemic and local risk factors and decide whether the use of the 3 mm punch biopsy needle with 7 mm blade is the most appropriate option for the species considered (human or veterinary) and for the specific lesion.

To ensure maximum safety, it is essential that the procedure is performed under aseptic conditions, with appropriate monitoring and availability of haemostasis and dressing materials. Use on pediatric, elderly or compromised tissue patients requires particular attention: the operator will have to calibrate the sampling depth and the tissue cylinder extraction maneuvers to minimize trauma and preserve the vitality of the sampled tissue. In the case of veterinary use, safety also requires the evaluation of the animal's behavior, the possible need for sedation or anesthesia and pain management in compliance with regulations and good veterinary practices.

If signs of infection, prolonged bleeding, excessive pain or other adverse events arise after the procedure, rapid clinical intervention is mandatory: this may include local haemostasis measures, antibiotic therapy if indicated, specialist assessment and, if necessary, supportive treatments. The safety of the 3 mm punch biopsy needle with 7 mm blade therefore depends not only on the characteristics of the device, but also on the appropriateness of the indication, the competence of the operator and the quality and sterility control procedures adopted in the healthcare environment.

Precautions

Before using the 3 mm punch biopsy needle with 7 mm blade, healthcare personnel must take all necessary precautions to reduce risks for the patient and the operator. It is essential to confirm the integrity of the sterile packaging and verify the absence of visible damage to the instrument; in case of compromised packaging the instrument must not be used. The operator must carry out an accurate medical history, evaluate anticoagulant therapies, known coagulopathies, allergies and the patient's general state, and plan the procedure including any bleeding control measures. Communication with the patient and obtaining informed consent are mandatory: the patient must be informed about the potential risks, the type of sample that will be collected and the post-procedural management methods.

In addition to precautions related to the patient, it is necessary to take care of the technical and logistical structure: preparing a sterile field, auxiliary instruments for hemostasis, adequate dressings, material for fixation and transport of the sample to the diagnostic laboratory, and personal protective equipment for the operator. During the procedure with the 3 mm punch biopsy needle with 7 mm blade it is necessary to limit unnecessary manipulations, perform the sampling with controlled movements and preserve the sample from crushing or contamination. Operators must be trained in the punch technique and tissue cylinder extraction maneuvers, so as to reduce the risk of artifacts that could compromise the histological examination.

The precautions also include the management of dangerous sharps waste: the 3 mm punch biopsy needle with 7 mm blade, once used, must be disposed of in sharps containers compliant with current regulations, to prevent puncture accidents and biological contamination. In case of complications during or after the procedure, such as persistent bleeding or local signs of infection, appropriate clinical protocols must be activated for management. Finally, general recommendations include recording the procedure in the clinical documentation, describing the site and conditions of the sampling and possibly sending information to the laboratory to facilitate the histopathological examination.

Method of administration

In the terminology provided by the format, "Method of administration" must be interpreted as the method of use of the device: the 3 mm punch biopsy needle with 7 mm blade must be used exclusively by healthcare personnel expert in the biopsy technique and in a suitable environment, guaranteeing aseptic conditions. The typical procedure involves the identification and marking of the site to be biopsied, local asepsis, possible local infiltrative anesthesia to reduce pain and the execution of the punch with controlled penetration to the desired depth. The 7 mm blade and 3 mm diameter of the punch allow you to obtain a tissue cylinder with optimal dimensions and quality for histological examination; it is essential to extract the sample with delicate handling techniques to avoid crushing and artifacts.

After introduction and cutting, the specimen should be removed and placed immediately in the appropriate fixation medium indicated by the laboratory (e.g. buffered formalin when indicated for pathological anatomy), correctly labeled and accompanied by relevant clinical information. The sampling site must then be treated with adequate haemostasis, sutures or dressings based on the size and location of the hole produced; Post-procedural management includes patient instruction on wound hygiene, warning signs, and how to remove dressings. If the sample is intended for special investigations (immunohistochemistry, molecular studies), it is advisable to communicate the storage and transport needs to the laboratory in advance.

Each phase of the procedure with the 3 mm punch biopsy needle with 7 mm blade requires attention to documentation: recording the description of the lesion, the location, the approximate dimensions, the technique used and any adverse events. The unused instrument must be stored in the conditions indicated to maintain sterility until use; after use, disposal must comply with local regulations for sharps and contaminated materials. The correct sequence of preparation, execution, sample management and post-procedure contributes significantly to the diagnostic effectiveness of the 3 mm punch biopsy needle with 7 mm blade and to patient safety.

Treatment program

The concept of "Treatment Program" for a diagnostic instrument such as the 3 mm punch biopsy needle with 7 mm blade concerns the operational recommendations and clinical guidelines inherent to the repeated or planned use of the biopsy procedure. Since it is not a drug with dosage schedules, planning must instead be based on clinical indications, the evolution of the lesion and subsequent diagnostic needs. For example, in a skin diagnostic procedure, performing a biopsy with the 3 mm punch biopsy needle with 7 mm blade could represent the first step to confirm a diagnosis; subsequently, the need for further sampling will depend on the histological results, the therapeutic response or the clinical evolution observed. In practice, the "program" involves the execution of scheduled samples when required by clinical follow-up, avoiding unnecessary repeated procedures which would increase the risk of complications and scarring.

In the context of chronic diseases or lesions that require monitoring, it is advisable to coordinate biopsies with clinical and laboratory tests to maximize the diagnostic information obtained from each sample. The 3 mm punch biopsy needle with 7 mm blade can be used in serial evaluations, as long as the planning takes into account the healing times of the biopsy site, the cumulative risk of scarring and the opportunity to alternate less invasive diagnostic techniques when possible. Furthermore, for lesions suspected of being neoplastic in nature, the diagnostic program could include, in addition to the initial biopsy, complementary tests and, if necessary, further sampling with techniques that allow wider margins or extension evaluations.

Clinical documentation and communication with the laboratory are essential elements in the program: clearly indicating the purpose of the biopsy (diagnosis, staging, search for particular markers) helps to define the sampling method and the storage needs of the sample. Finally, the decision to repeat a biopsy with the 3 mm punch biopsy needle with 7 mm blade must always be guided by the multidisciplinary evaluation of the histological results and the overall clinical situation, favoring approaches that balance the diagnostic value with respect for the safety and comfort of the patient.

Target species

The product wording "punch biopsy needle 3 mm blade 7 mm" does not a priori limit the target species, but defines its functionality for the collection of small tissue samples. In general, the use is aimed at human subjects in a clinical setting and can also be adapted to veterinary contexts, provided that the procedure is performed by qualified personnel and that species-specific anatomical and behavioral considerations are adequately evaluated. The choice to use the 3 mm punch biopsy needle with 7 mm blade on different species depends on the size and thickness of the skin or target tissue: in smaller species or in small anatomical areas, the diameter of the punch (3 mm) and the 7 mm blade may be adequate to obtain a representative sample without causing excessive damage.

For human use, the instrument is indicated for dermatological examinations, outpatient skin sampling and minimally invasive surgical procedures, always under the responsibility of a healthcare professional. In the veterinary field, the same logic applies but requires adaptations relating to sedation, pain management and behavioral control of the animal to ensure operator safety and sample quality. Regardless of the species, the pre-procedural evaluation must include elements relating to tissue physiology, the specificities of the skin and the possible presence of pathologies that can alter healing.

In conclusion, the 3 mm punch biopsy needle with 7 mm blade is an instrument intended to collect tissue samples in a targeted and minimally invasive way; its application on different species and clinical situations always requires an individual evaluation conducted by trained professionals, with attention to the technique, patient management and safety and hygiene standards that regulate biopsy practice.

Product Details

Gruppo Terapeutico
Attrezzature veterinarie
Forma Farmaceutica
Aghi
Tipologia
Libera vendita

Product Reviews / Q&A

Average rating

0.0
0 Review
★★★★★ Excellent 0
★★★★☆ Good 0
★★★☆☆ Medium 0
★★☆☆☆ Poor 0
★☆☆☆☆ Terrible 0

  • Reviews (0)
  • Questions & Answers (0)
Product added to wishlist