• -10%
  • New
Foqus USP 1 Triangular Needle 1 Unit
Foqus USP 1 Triangular Needle 1 Unit

Foqus USP 1 Triangular Needle 1 Unit

Foschi
Prodotto Disponibile
€5.00 €5.55 -10%
Tax included
Sterile and resistant triangular needles, ideal for surgical and veterinary procedures. They offer precision, control and safety for effective suturing and rapid healing.

Description

Foqus USP 1 is a high precision triangular needle, individually packaged in a sterile unit, specifically designed to ensure high performance during surgical and veterinary procedures. This needle stands out for its triangular profile which ensures effective tissue penetration, minimizing trauma and allowing clean and precise cuts. Thanks to its lightness and optimal size, it offers superior handling which reduces operator fatigue even in the longest or most complex procedures. Ideal in both the medical and veterinary fields, the needle ensures reliable closure of wounds and contributes to faster healing of the patient, preserving the integrity of the tissues involved.

The triangular shape allows absolute control during insertion into dense or resistant tissues. Thanks to its compatibility with USP 1 sutures, it is particularly suitable in situations where the mechanical support obtained from the suture must be high. The sharp tip ensures maximum efficiency in passing through fibrous tissues, while reducing the risk of fraying of the suture material.

Sterilization preserves the purity of the needle until use. Individual packaging ensures that each unit is free of environmental contaminants, rigorously meeting the safety and hygiene standards needed in the hospital or outpatient setting.

Therapeutic Indications

Foqus USP 1 Triangular Needle is indicated for all procedures that require rapid, precise and safe tissue penetration, especially in cases involving particularly resistant tissues such as skin, subcutaneous tissue, aponeurosis, muscle and other fibrous structures. The needle is widely used in both general surgery and specialist surgery, including areas such as veterinary surgery, trauma suturing, abdominal surgery and the suturing of large skin lacerations. Being compatible with USP 1 suture material, it allows a robust wound closure, counteracting the possibility of dehiscence or accidental openings. It is recommended when high tensile strength and safety are needed during the suturing process, even in cases of minimal invasiveness or limited access.

In a veterinary environment, the needle is ideal for medium and large animals, where the need to pass through skin and often robust fabrics is daily. It can also be used in the treatment of large lesions, skin flap fixation, reconstructive plastics and other surgical practices where precision and safety are paramount. Thanks to its particular geometry and surface treatment, it minimizes the risk of infections and facilitates optimal healing, while ensuring excellent intraoperative control and excellent resistance to bending and breakage.

Composition

Material: The needle is made of high-strength medical stainless steel, selected to ensure durability, biocompatibility and the ability to maintain constant sharpness even during repeated passages through tissues. The steel used guarantees excellent resistance to oxidation and corrosion, a fundamental characteristic for use in humid environments and in contact with blood. The triangular tip is machined to advanced sharpening standards to maintain cutting ability throughout the procedure, without risk of accidental bending or loss of efficiency.

The surface of the needle is polished and treated to reduce friction with the tissues, thus facilitating every movement during the suturing phase. The unit is packaged in a sterile individual blister, often made of medical plastic material and medical paper, which protects the product from external contamination until the moment of actual use in the operating room or clinic.

Contraindications

Foqus USP 1 Triangular Needle must not be used in subjects with known hypersensitivity or allergy to metals, in particular to stainless steel or metals present in it. Use is contraindicated in all those situations in which the surgeon intends to avoid deep penetration into the tissues or where atraumatic or round tip needles are required. Do not use on particularly friable or highly vascularized tissues where the sharp tip and triangular shape could increase the risk of accidental injury to adjacent vascular or nervous structures. In case of doubt about the compatibility of the device with the selected suture materials, it is advisable to opt for alternative solutions recommended by expert medical personnel.

Safety of the drug for the species

The use of Foqus USP 1 Triangular Needle, correctly sterilized and used according to indications, has a high safety profile in both the human and veterinary fields. The design allows precise control of the entry point and depth of penetration avoiding accidental damage to surrounding tissues. However, as with any surgical instrument, safety strongly depends on the manual skill and experience of the operator: the risk of direct injury to tissues, vascular or nervous structures remains present especially in complex interventions. The needle, being equipped with a sharp tip and triangular section, must be handled with caution to prevent involuntary trauma to both the patient and healthcare personnel.

In case of improper use, such as excessive force or non-recommended angles, there is the possibility of breakage or bending, with consequent risk of retention of fragments in the body. Safety is guaranteed by scrupulously respecting the handling guidelines and disposal procedures of the device after use. Before reusing any surgical instrument, careful verification of structural integrity and sterility is recommended for each use.

Precautions

The product must be used exclusively by personnel properly trained in the use of triangular surgical needles. It is recommended to handle the needle with suitable tools to avoid accidental injuries during setup, use and removal from the package. If the packaging appears damaged, do not use the unit and dispose of it according to current regulations for contaminated medical devices.

Always use sterile gloves and follow asepsis procedures to reduce the risk of infection. Never leave needles or suture materials unattended on non-sterile surfaces. Children and untrained people must be kept away from the area of ​​use. Always check the integrity of the tip and the structure of the needle before use to avoid complications. Dispose of any used needles in appropriate sharps containers and comply with local biomedical waste disposal procedures.

Method of administration

The Foqus USP 1 needle must be used by mounting it on the needle holder, making sure that it is firmly fixed before introducing it into the tissues. Insertion must take place following the natural curve of the triangular tip to allow easy crossing of the different stratifications without excessive forcing. If greater visibility or control is required, the use of special forceps is recommended for holding throughout the entire procedure.

Once the suture is completed, the needle should be carefully removed and disposed of immediately in the appropriate sharps containers. Never reuse the same unit on multiple subjects or attempt home sterilization because this would not guarantee the restoration of the required aseptic conditions. Delicate handling is recommended to avoid deformation of the tip and ensure maximum efficiency throughout the procedure.

Treatment program

Foqus USP 1 Triangular Needle is used during the single surgical session in correspondence with the need for suturing. The duration of use is therefore closely related to the type, extent and difficulty of the surgical or veterinary procedure. At least one new, sterile needle must be used for each patient and for each surgical access. For interventions of significant duration or complexity, it is suggested to prepare several identical sterilized needles, in order to proceed with maximum efficiency and avoid any unscheduled breaks.

Immediate replacement of the needle is recommended if the device shows signs of wear, bending, loss of sharpness or in the presence of any manufacturing defect detected during use. The wound treatment protocol involves the use of needles and suture materials for both primary and secondary closures, always following the instructions for choosing the caliber and shape appropriate to the size and type of injured tissue. For each procedure, it is always recommended to follow the rules of good surgical practice which provide for the appropriate change of instruments for each patient in order to preserve safety and hygiene.

Target species

The needle is intended for all animal species that require surgical suturing on resistant tissues or in conditions that require high performance in terms of cutting and precision. Widely used in veterinary medicine for dogs, cats, horses, farm animals and pets in the presence of wounds requiring suturing, traumatic injuries or planned interventions. It is suitable for both small and large animals, with particular effectiveness in cases that require speed, safety and ergonomic handling typical of the modern veterinary surgical sector.

Product Details

Gruppo Terapeutico
Attrezzature veterinarie
Forma Farmaceutica
Aghi
Tipologia
Libera vendita

Product Reviews / Q&A

Average rating

0.0
0 Review
★★★★★ Excellent 0
★★★★☆ Good 0
★★★☆☆ Medium 0
★★☆☆☆ Poor 0
★☆☆☆☆ Terrible 0

  • Reviews (0)
  • Questions & Answers (0)
Product added to wishlist