• -10%
  • New
Anesthesia Flask 2 Liters Green
Anesthesia Flask 2 Liters Green

Anesthesia Flask 2 Liters Green

Non disponibile
€16.43 €18.25 -10%
Tax included
2 liter green anesthesia bag, resistant and easy to use, guarantees safe and effective ventilation during veterinary and hospital interventions, even in emergencies.

Description

The 2 Liter Green Anesthesia Bag is a fundamental tool used for the management and control of the airways during anesthetic procedures, in veterinary contexts as well as in specific hospital settings. Featuring a capacity of 2 litres, the bag is designed in resistant and elastic material, allowing effective manual ventilation of the patient to be guaranteed. Its green color, in addition to facilitating rapid recognition between the instruments of the anesthetic kit, is used to reduce visual stress on healthcare personnel and improve the management of instruments, especially in emergency situations.

The anesthesia bag is inserted into the appropriate anesthetic circuit and acts as a tank that allows the mixture of anesthetic gas and oxygen to be accumulated, ready to be delivered and conveyed into the patient's lungs through simple manual compression. This solution is indispensable both for assisted ventilation, for example during short and long-term general anaesthesia, and for manual oxygenation in situations in which the patient is not able to breathe independently. The choice of a 2 liter capacity makes the bag suitable for a wide range of patients, from medium sized to larger ones, providing operational flexibility within the operating room or veterinary clinic.

The design of the Green Anesthesia Ball includes a non-slip surface, designed for a comfortable and safe grip even after prolonged handling, minimizing the risk of accidental slipping due to humidity or liquid residues. Furthermore, the standardized connection valve ensures a quick and safe connection with the anesthetic circuits, guaranteeing a perfect seal and reducing the possibility of leaks of gas or anesthetic mixtures. This aspect is particularly relevant for maintaining maximum environmental safety in the operating area, reducing staff exposure to anesthetic vapours.

Therapeutic Indications

The 2 Liter Green Anesthesia Bag is indicated during general anesthesia for controlled or assisted manual ventilation of patients who cannot independently maintain adequate respiratory function. It is particularly recommended as a support in surgical procedures where precise control of ventilation is necessary, both for the safety of the animal and for the success of the operation. Furthermore, it is used during post-operative awakening, offering the possibility of providing supplementary oxygen in cases where the resumption of independent breathing is slow or irregular.

The therapeutic indications also include the management of respiratory emergencies, such as in cases of airway blockage, respiratory arrest or during cardiopulmonary resuscitation. The bag represents an essential tool for emergency ventilatory support maneuvers in clinics, hospitals, veterinary clinics and on the move during patient transport. It is suitable for use in all procedures where controlled manual ventilation must be ensured for short or long periods, facilitating constant monitoring of the patient's chest movements and respiratory compliance.

Thanks to its 2 liter capacity, it is suitable for use on a wide range of patients, from medium and large dogs to small animals that require a higher gas reserve. The use of the balloon, combined with adequate monitoring systems, finally contributes to maintaining optimal levels of oxygenation, promoting the hemodynamic and metabolic stability of the animals undergoing surgery.

Composition

Materials: The 2 Liter Green Anesthesia Bag is made of high quality medical rubber or synthetic material, suitable for applications in the healthcare sector. The choice of material ensures high elasticity, tensile strength and long life even after numerous cycles of use, maintaining the correct original shape and full mechanical functionality.

The internal and external surfaces of the flask are designed not to retain gas residues, facilitating cleaning and disinfection after each use. The material is also designed to be biocompatible and hypoallergenic, reducing the risk of cross-contamination between one patient and another. The green color is obtained using non-toxic pigments, which do not degrade or release potentially harmful substances in contact with anesthetic gases or residues from clinical procedures.

Components: It includes a universal connection valve made of plastic or rigid rubber which allows safe and standardized connection to the anesthetic circuit tubes. The welding and joining of the parts are carried out to ensure complete gas tightness, avoiding micro leaks even during prolonged manual pressure. The entire product is latex-free, to minimize the risk of allergies in patients and operators.

Contraindications

The use of the 2 Liter Green Anesthesia Bag is contraindicated in cases where ventilatory support is not required or where there is serious damage to the airways which prevents correct manual ventilation. It should not be used on patients sensitized to any constituent materials, although the product is made to be hypoallergenic and compatible with the clinical environment. Incorrect use, not compliant with assisted ventilation guidelines or with excessive pressures, can cause trauma to the airways and pneumothorax, especially in small animals or with compromised lung conditions.

Use not recommended in the absence of adequate monitoring of vital signs and without specific training on manual ventilation techniques. Avoid use on patients in whom a congenital malformation of the respiratory tract has been found which could compromise correct functioning or lead to immediate complications. Do not use in circuits other than those approved or modified, to prevent accidents caused by incompatibility of valves or connection pipes.

Safety of the drug for the species

The 2 Liter Green Anesthesia Balloon, although not a drug but a medical device, represents a tool of primary importance for the safety of the animal patient during anesthetic procedures. Its use promotes precise and adjustable manual ventilation, reducing the risks linked to hypoxia or hyperventilation. Use on animals of smaller weight or size must be carefully calibrated, modulating the pressure exerted on the balloon to adapt to the patient's lung capacity, avoiding the possibility of iatrogenic damage resulting from pulmonary over-distension.

The safety guaranteed by the non-slip design and biocompatible materials reduces the risk of contamination and facilitates management in high-turnover clinical environments. The ability to provide immediate and effective ventilatory support is fundamental for the speed of intervention in emergencies and in daily anesthetic practice. The use of the balloon must always be combined with accurate monitoring of respiratory exchanges, both through direct clinical observation and through instrumental monitoring systems, to ensure that all parameters remain within safe physiological limits for the species being treated.

Precautions

It is recommended to always check the structural integrity of the 2 Liter Green Anesthesia Bag before each use, checking for the presence of any micro-cracks, cracks, surface alterations or defects in the connection valve, which could compromise the safety of the operator and the patient. It is important to replace the balloon immediately if you notice a loss of seal or reduced elasticity and ability to return to its original shape. Healthcare workers must wear personal protective equipment to avoid accidental exposure to residual inhaled gases or biological materials when handling the circuit.

Never leave the device unattended in the presence of patients or children. After use, proceed with thorough cleaning following the indications of the internal protocol of the healthcare or veterinary facility, using non-aggressive detergents and disinfectants that do not alter the physical-chemical characteristics of the material. Store the ball in a clean, dry environment and away from sources of excessive heat or direct solar radiation which could cause premature aging of the materials.

It is advisable to train staff in the correct use of the balloon, with particular attention to the pressure exerted to avoid barotraumas in patients of smaller size or with pre-existing lung pathologies. If in doubt about compatibility with equipment already in use, contact an expert technician before operational use.

Method of administration

The 2 Liter Green Anesthesia Bag connects securely to the anesthetic circuit via the standardized valve, ensuring that the connection is stable and free of leaks. During the procedures, manual ventilation is carried out by compressing the bag with a regular rhythm and adequate pressure, carefully observing the patient's thoracic expansion.

It is good practice to adapt the frequency and intensity of compression according to the body weight, clinical needs and respiratory response of the treated subject. For prolonged interventions, it is recommended to alternate operators to avoid fatigue and maintain constant ventilatory effectiveness. In emergency phases, the balloon must be immediately available and easily accessible, already connected to the circuit to ensure a timely response. At the end of the session, the device must be disconnected, cleaned and sterilized as recommended.

Treatment program

The use of the 2 Liter Green Anesthesia Bag is not subject to a fixed treatment program, but depends on the clinical needs of the patient and the duration of the anesthetic procedure. In scheduled operations, it is advisable to check the efficiency of the device before and during use, to ensure continuity of ventilatory support. In emergency contexts, the bag must be used with rapid cycles of manual ventilation until the patient is stabilised, according to international resuscitation guidelines.

During maintenance anesthesia, the bag is used to regulate respiratory exchanges, carrying out controlled ventilation cycles according to the indications of the anesthetist and the mechanical ventilator, if present. During the awakening phase, manual ventilation can be prolonged to facilitate the elimination of anesthetic residues and support the return to spontaneous breathing. Any repetitions or prolonged use must be evaluated based on individual clinical conditions and carefully monitored to avoid risks of respiratory fatigue or secondary complications.

Target species

The 2 Liter Green Anesthesia Bag is intended for use on medium and large animals, including dogs and, where necessary, other species of a size compatible with the 2 liter volume of the device, such as some laboratory or zoo animals. It is particularly suitable in veterinary fields, both for companion animals and for those of zootechnical interest. The versatility of the bag allows its use in different clinical situations, from surgical operations to emergency procedures, providing an efficient and safe solution for manual ventilation.

Product Details

Gruppo Terapeutico
Attrezzature veterinarie
Forma Farmaceutica
Dispositivi
Tipologia
Libera vendita

Product Reviews / Q&A

Average rating

0.0
0 Review
★★★★★ Excellent 0
★★★★☆ Good 0
★★★☆☆ Medium 0
★★☆☆☆ Poor 0
★☆☆☆☆ Terrible 0

  • Reviews (0)
  • Questions & Answers (0)
Product added to wishlist