• -10%
  • New
Foqus USP 2.0 Triangular Needle 2.0 mm
Foqus USP 2.0 Triangular Needle 2.0 mm

Foqus USP 2.0 Triangular Needle 2.0 mm

Foschi
Prodotto Disponibile
€4.67 €5.19 -10%
Tax included
2.0 mm triangular surgical needle, ideal for precise and delicate sutures. Resistant, easy to handle and safe, it guarantees accurate interventions, reducing trauma and promoting rapid healing.

Description

Foqus USP 2.0 Triangular Needle 2.0 mm is a precision surgical instrument designed to meet the needs of medical procedures requiring extreme accuracy and reliability. Thanks to its triangular tip, it allows optimal penetration into the tissues, minimizing trauma and bleeding for the patient. The needle measures 2.0 mm, which makes it particularly suitable for those practices that require great delicacy and total control when performing the sutures. Designed for professional use, this device is characterized by excellent handling and the ability to maintain its efficiency even after several applications. The quality of the materials used guarantees high resistance to bending and breakage, offering the surgeon a safe and high-performance instrument during all phases of the operation.

The Foqus USP 2.0 needle is specially designed to assist professionals in the treatment of both superficial and deep tissues, where precision of insertion and traction are fundamental. The use of the triangular tip also allows a uniform distribution of the applied force, limiting the risk of lacerations and making the suture more linear and cleaner. The instrument is compatible with various types of suture threads, making it versatile in different operating contexts. The uniformity of production and constant attention to detail ensure the absence of imperfections and a reliable final result, minimizing the possibility of intraoperative complications due to inadequate performance of the instrument.

Therapeutic Indications

This surgical needle is indicated for all suturing procedures that require precise penetration through soft tissue, such as in general, plastic, vascular and many other surgical specialties. Foqus USP 2.0 Triangular Needle 2.0 mm is particularly recommended when meticulous control of the direction and depth of penetration is required, a fundamental element for minimizing trauma and promoting rapid tissue healing. It is used both in hospital environments and in private clinics for the closure of surgical wounds, suturing of internal organs and manipulation of delicate tissues. The use of this needle can reduce the risk of the onset of infections thanks to the excellent finishing and the minimization of tissue trauma.

One of the main therapeutic indications concerns microsurgery practices where the precision in the insertion and exit of the needle is crucial for the successful matching of the margins. The triangular design makes the tip extremely effective in separating the fibers without jagging, thus allowing faster healing with fewer residual marks. The Foqus USP 2.0 is also used in outpatient and emergency room procedures, making it ideal for all situations where high precision and safety suturing is required. The use in manipulations of small vessels, nerves or during the reconstruction of damaged tissues represents a further strong point, demonstrating its therapeutic versatility.

Composition

Needle Material: The triangular needle is made of high-quality medical steel selected for its resistance to corrosion, bending and breakage. This material maintains structural integrity during repeated use, preventing deformation of the triangular tip. The medical steel is subjected to scrupulous surface treatments to increase smoothness in the tissues, minimize friction during penetration and maintain the sterility of the device. The total absence of allergens or substances that can cause adverse reactions in patients is also guaranteed.

The surfaces of the needle are worked with precision technologies that eliminate any imperfection visible to the naked eye, thus offering maximum safety both during the insertion and traction phases. The triangular structure provides strength and precision, while the 2.0 mm caliber has been designed to balance resistance to bending with the ability to pass through tissue without causing excessive damage. The composition of the needle complies with all the criteria of international regulations for medical devices, ensuring compatibility with the main suture threads used in surgery.

Contraindications

The use of the triangular Foqus USP 2.0 needle is contraindicated in all cases in which a known hypersensitivity or allergy to medical steel has been ascertained, although this eventuality is extremely rare thanks to the quality of the materials used. Avoid using the instrument in procedures that require needles of different shapes for specific anatomical or interventional needs, such as in the case of particularly delicate tissues where a needle with a round tip or one with less invasive characteristics is necessary. Do not use in the presence of contamination or visible damage to the needle, such as bends, chipping or oxidation, to avoid the risk of intraoperative or postoperative complications.

Further contraindications emerge in situations where the triangular structure of the needle could cause excessive traumatism, such as in subjects with reduced healing capacity or compromise of the tissues themselves. Use in pediatric or geriatric patients is not recommended without careful evaluation of the risk-benefit ratio. In the presence of extensive skin pathologies or ongoing infections at the insertion site, consult your doctor beforehand for appropriate evaluation. Avoid reusing the needle, especially in multi-patient environments, to prevent cross-contamination and nosocomial infections.

Safety of the drug for the species

The safety of use of Foqus USP 2.0 Triangular Needle 2.0 mm has been evaluated taking into account the particular needs of each surgical procedure in human patients. Compliance with good surgical practices and guidelines regarding the use of sterile instruments significantly reduces the possibility of device-related complications. In conditions of correct handling, this needle maintains its safety of use thanks to a design that limits the risk of breakage, anomalous bending or release of metal micro-particles into the tissues.

The interaction of the needle with biological tissues has been studied to minimize the inflammatory response and promote optimal healing processes. Particular attention must be paid to the sterility and integrity of the original packaging: only a correctly sterilized and stored needle allows you to reduce the risk of infections or cross-contamination. When disposing, follow local procedures for the management of sharps and potentially infectious objects. Compliance with all these measures guarantees the safety of both healthcare workers and patients when using the Foqus USP 2.0.

Precautions

It is essential to carefully inspect the Foqus USP 2.0 Triangular Needle 2.0 mm before use, checking that there are no structural alterations, damages or defects that could compromise its functionality. Always use the needle in a sterile environment and only by trained medical personnel. Ensure adequate lighting and visibility of the operating field during all suturing phases to avoid positioning errors that could cause damage to the surrounding tissues. It is recommended to avoid excessive forcing which could cause the needle to bend or break.

Pay particular attention during procedures on patients with fragile tissues or in critical clinical conditions, customizing the choice of instrument based on the specific needs and general conditions of the patient. After each use, disposal must take place in accordance with current regulations for sharp medical devices, avoiding any improper handling that could expose operators or other individuals to the risk of accidental bites. Compliance with good management practices and staff training are key elements to ensure maximum safety during all surgical operations involving the use of this triangular needle.

Method of administration

The needle must be used according to the appropriate suturing techniques for the type of tissue and planned surgical intervention. Insert the triangular tip into the tissue with controlled and progressive movements, ensuring the correct angle of penetration to minimize damage to the structures involved. It is recommended to grasp the needle with suitable surgical forceps to avoid slipping and obtain optimal control during its passage through the tissues. In case of excessive resistance, avoid twisting movements that could damage the tip or deform the structure.

The needle can be used with most compatible surgical wires with a diameter of 2.0 mm. It is recommended to apply uniform traction to ensure the integrity of the suture and prevent tears or breaks. After use, the needle must be immediately disposed of in the appropriate sharps container, without attempting to reuse it. Observance of the correct handling methods reduces the risk of complications and guarantees the maximum therapeutic benefit of the instrument.

Treatment program

The adoption of Foqus USP 2.0 Triangular Needle 2.0 mm follows the standard protocols for surgical suturing, adapting to the different needs based on the type of operation and the patient's clinical condition. The frequency and method of use are dictated by surgical needs immediately following the completion of invasive procedures requiring tissue reconstruction or repair. The needle is generally changed between patients, in compliance with guidelines on the prevention of cross-infections and to maintain high hygiene standards.

The treatment program may involve the use of needles of different diameters or shapes depending on the progression of the procedure or the presence of any complications. In particularly long or complex operations, provide spare needles ready for use to quickly replace any damaged or used needle. For each type of operation, consult the specific guidelines of each surgical specialty which govern their choice, arrangement and use during the procedures. This allows for optimal management of the sutural treatment and guarantees the patient the best possible results.

Target species

The Foqus USP 2.0 2.0 mm triangular needle is designed specifically for human use. Thanks to its characteristics of precision, robustness and safety, it finds ideal application in various branches of surgical medicine, meeting the needs of specialists and operating teams engaged in suturing and tissue reconstruction activities. Its properties allow it to be used both in general surgery and in more specialized disciplines, such as microsurgery, plastic surgery, vascular surgery and the suturing of internal organs or delicate structures.

Although the primary destination is use on human patients, the technical characteristics of the needle also make it suitable for complementary uses in research laboratories or during practical exercises on biological samples. However, use on other species must always be evaluated in accordance with the specific anatomical-physiological needs and after careful analysis of the risks and benefits.

Product Details

Gruppo Terapeutico
Attrezzature veterinarie
Forma Farmaceutica
Aghi
Tipologia
Libera vendita

Product Reviews / Q&A

Average rating

0.0
0 Review
★★★★★ Excellent 0
★★★★☆ Good 0
★★★☆☆ Medium 0
★★☆☆☆ Poor 0
★☆☆☆☆ Terrible 0

  • Reviews (0)
  • Questions & Answers (0)
Product added to wishlist