The 35 Staple Large Version Stapler is a surgical instrument designed to speed up and optimize the process of closing skin wounds during surgical operations. It stands out for its particular ability to apply 35 staples safely and precisely, ensuring broad coverage and stability of the suture. The large shape of the instrument allows you to work comfortably even on large surfaces, facilitating the task both in general and specialist surgery contexts, such as trauma, plastic and veterinary surgery. Thanks to the construction with high quality materials, this stapler offers great reliability, easy handling and durability, while guaranteeing operator safety at the same time. The ergonomic handle and progressive staple application system reduce hand fatigue and ensure uniform staple release. This product responds to the need for speed and precision required by interventions that require effective and quick closure of skin flaps or surgical incisions, minimizing the risk of infections and ensuring an optimal aesthetic result. Completely disposable, it represents a hygienic solution that eliminates the risk of cross-contamination and reduces the need for additional sterilization tools. Thanks to its robust and reliable structure, the 35 Staple Large Version Stapler is also suitable in emergency environments or for procedures that require timely and safe stapling.
Therapeutic Indications
The 35 Staple Large Version Stapler is designed for the mechanical suturing of surgical incisions or traumatic skin wounds in different types of patients and in various clinical contexts. Its main applications concern the rapid and safe closure of skin flaps after highly complex operating procedures, such as those in the general surgical, orthopedic, plastic, gynecological, veterinary and emergency rooms. In particular, it is useful in cases where it is necessary to apply staples on large skin extensions through a single maneuver, saving precious time compared to manual suturing with needle and thread. It is favored in cases of polytraumatized patients, in emergency operations, for the management of incisions in major surgery and for the closure of skin flaps in pediatric and adult patients. Also used in complex outpatient procedures and during the preparation of skin grafts, the stapler is essential for reducing operating times and limiting the time the wound is exposed to the external environment. Furthermore, its use represents a valid support for the control of localized blood loss and for reducing the risks of post-surgical infection, ensuring effective alignment of the skin margins and promoting optimal healing. It is also indicated in all situations that require rapid immobilization of the tissues during the pre- and post-operative phases.
Composition
The 35 Staple Large Version Stapler is entirely made with high quality materials that meet the strictest safety and health compliance standards. Its main components include a rigid, resistant and lightweight plastic structure, designed to ensure easy handling and comfort of use. The staples are made of surgical grade medical stainless steel, specially treated to ensure perfect biocompatibility with tissues and minimize any risk of allergic or inflammatory reaction. The staple release mechanism is designed to promote even distribution of stitches along the suture line, preventing both overlap and excessive spacing of metal clips. The ergonomic and non-slip handle is designed to offer firm control even during the most delicate or prolonged maneuvers. All components are specifically made for single-use use, thus eliminating the risk of cross-contamination. The materials used are selected to guarantee hygiene, resistance and the ability to withstand the forces applied during skin closure procedures on large surfaces or on particularly thick or rigid tissues.
Contraindications
The use of the 35 Staple Large Version Stapler is contraindicated in patients who have a particular sensitivity to the metallic materials constituting the stitches, such as stainless steel, as well as in all cases of subjects with demonstrated hypersensitivity to the plastic components of the device. Furthermore, the use of this instrument is not recommended in the presence of infected wounds or with severe contamination, since rapid closure can trap pathogens and prevent correct drainage, favoring the onset of deep infections. It is not indicated for the suturing of internal tissues, organs or blood vessels and in situations that require very precise alignment of the wound edges, as occurs in some detailed aesthetic plastic surgery procedures or where the healing result is essential. We also do not recommend using it on highly cavernous lesions that are too thick or subject to high tension, which could lead to slippage or dehiscence of the stitches. It is not suitable for patients with known healing disorders, nor for wounds with non-vital or necrotic margins. The device must not be reused or opened before use.
Product safety for the species
The 35 Staple Large Version Stapler is designed to ensure maximum safety of use in surgical and outpatient environments. Thanks to the quality of the medical stainless steel of the stitches, the risks of adverse reactions or infections related to the implant are significantly reduced. The controlled stitch application system prevents excessive penetration into the tissues, ensuring that each staple is positioned at the right depth, thus guaranteeing stability and protection of the wound. Disposable use eliminates any risk of cross-contamination between patients, making the product suitable even in departments with high infectious risk or emergency contexts. The ergonomics of the instrument and its lightness contribute to reducing the risk of operative trauma during rapid maneuvers, facilitating homogeneous and precise application. Despite the high safety of the product, it is still essential to follow the guidelines for use and hygiene regulations, using the stapler only and exclusively on intact or vitalized skin.
Precautions
Before applying the 35 Staple Large Version Stapler it is essential to carefully evaluate the state of the wound and the skin conditions. Correct decontamination of the surgical area, as well as compliance with aseptic procedures during surgery, are essential to prevent local infections or post-operative complications. Operators must verify that the edges of the wound are well approachable and vital before suturing. It is recommended not to use the device on excessively thin, severely traumatized or infected skin. It is important to use the stapler firmly and decisively, taking care to distribute the stitches evenly to avoid overlapping or areas without coverage, which could compromise the stability of the suture. After use, dispose of the device according to current regulations for sharps and contaminated medical waste. Never attempt to reuse the instrument or open the package before actual use. It is advisable to check the wound regularly over the next few days for signs of infection or stitch dehiscence. Operators must adequately protect themselves from possible splashes or contact with blood and biological materials during the application of the suture.
Method of administration
The 35 Staple Large Version Stapler must be used exclusively by qualified healthcare personnel. Before use it is necessary to ensure that the wound has been adequately cleaned, decontaminated and that the edges have been aligned manually. The end of the stapler is positioned perpendicular to the edge of the wound and firm pressure is applied to the handle to release the metal staple. Each pressure releases a point that closes the edges of the skin, ensuring stability and speed of the operation. The process must be repeated along the entire length of the wound, maintaining a regular distance between the points to ensure an optimal result from both a functional and aesthetic point of view. At the end of the procedure, the tightness of the applied staples is checked and the area is immobilized according to the established protocols. The device is then disposed of immediately in the sharps container. It is not necessary to use auxiliary tools to remove the sterile device from the packaging, which must be opened immediately before use.
Treatment program
Wound treatment using the 35 Staple Large Version Stapler must be personalized based on the length, depth and location of the incision or skin lesion. Generally, the removal of staples occurs after 7-14 days depending on the skin area treated and the patient's regenerative capacity. In cases of large incisions or wounds subjected to high mechanical tension, more frequent surveillance and possible differentiated removal of the staples may be necessary. The device allows for coverage with 35 stitches, which can be sufficient for most standard surgical wounds; for larger lesions it is possible to use multiple staplers consecutively. After closure, a sterile bandage is applied and its progress is monitored until the skin is completely healed. It is essential that the inspection and removal of the stitches are carried out by healthcare professionals to avoid complications, including infections, dehiscences or unaesthetic scarring. The post-suture treatment protocol includes regular checks, hygiene of the area and monitoring for the possible appearance of bruises, pain or signs of complications.
Target species
The 35 Staple Large Version Stapler is intended for use on humans and, based on the needs of the veterinary professional, also on medium and large sized animals that require a large and resistant skin suture. It is suitable for adult, pediatric and geriatric patients, provided that the evaluation of the skin tissue and general conditions allows the application of staples. Its use in veterinary medicine focuses in particular on the closure of large traumatic or surgical wounds in dogs, cats, pets and livestock. In animals, the choice of metal stapler can be evaluated on a case-by-case basis based on the tendency for skin healing and the size/strength of the tissue to be sutured, under close supervision of the expert professional.